Date Doc # Type Category Work Done / Notes Total File
11/9/2018 SC181240 Invoice Heat / Furnace Inspected unit for not heating; unit tripped on low gas pressure switch; reset switch, restarted unit, verified operation. $217.50 PDF
3/28/2019 SC181262 Invoice Heat / Air Turnover Saturday no-heat service call: air turnover unit not firing; combustion motor running backwards causing wires to short; repaired wiring, replaced blown fuses, restarted and verified. Provided spare airflow switch. Freight UPS 4/1/19. $1,081.67 PDF
12/4/2020 SC201161 Invoice Heat / Furnace No heat: unit off on low pressure gas switch due to gas valve shut off; opened valve, reset gas pressure switch, started unit; cycled several times to verify operation. $394.50 PDF
8/4/2021 SC210844 Invoice AC / Condensing Unit Inspected/repair office condensing unit; compressor failed; verified condenser fan & capacitor working; left compressor shut off; GRIPS to provide pricing on replacement parts. $704.00 PDF
8/12/2021 PR21152 (ref Q8671) Invoice System Replacement (Furnace + AC) Project to replace split system feeding the office area at Soccer Stop. Reference quote Q8671. $10,675.00 PDF
12/18/2023 SC231162 Invoice Controls / Timer Air Rotation Unit not cycling properly; timer failed stuck on override. Installed new timer and programmed schedule (Mon–Fri 3:00pm–12:00am; Sat–Sun 6:00am–12:00am). Verified operation. GRIPS to quote duct work per request. $1,812.88 PDF
3/8/2024 SC240273 Invoice Damper Service request to reconnect damper. Reconnected and opened damper per request; verified proper operation. $315.50 PDF
1/16/2025 Invoice 2173 Invoice Heat / Air Rotation Emergency call: air rotation unit not operating; found thermostat set to 55°F; adjusted above 55°F and unit ran. Inspected belts/motors OK; outside-air dampers previously unhooked; monitored ~1 hour, no high-limit trip. Communicated findings via text. $442.50 PDF
11/9/2018
SC181240
Total
$217.50
Invoice Heat / Furnace
Inspected unit for not heating; unit tripped on low gas pressure switch; reset switch, restarted unit, verified operation.
3/28/2019
SC181262
Total
$1,081.67
Invoice Heat / Air Turnover
Saturday no-heat service call: air turnover unit not firing; combustion motor running backwards causing wires to short; repaired wiring, replaced blown fuses, restarted and verified. Provided spare airflow switch. Freight UPS 4/1/19.
12/4/2020
SC201161
Total
$394.50
Invoice Heat / Furnace
No heat: unit off on low pressure gas switch due to gas valve shut off; opened valve, reset gas pressure switch, started unit; cycled several times to verify operation.
8/4/2021
SC210844
Total
$704.00
Invoice AC / Condensing Unit
Inspected/repair office condensing unit; compressor failed; verified condenser fan & capacitor working; left compressor shut off; GRIPS to provide pricing on replacement parts.
8/12/2021
PR21152 (ref Q8671)
Total
$10,675.00
Invoice System Replacement (Furnace + AC)
Project to replace split system feeding the office area at Soccer Stop. Reference quote Q8671.
12/18/2023
SC231162
Total
$1,812.88
Invoice Controls / Timer
Air Rotation Unit not cycling properly; timer failed stuck on override. Installed new timer and programmed schedule (Mon–Fri 3:00pm–12:00am; Sat–Sun 6:00am–12:00am). Verified operation. GRIPS to quote duct work per request.
3/8/2024
SC240273
Total
$315.50
Invoice Damper
Service request to reconnect damper. Reconnected and opened damper per request; verified proper operation.
1/16/2025
Invoice 2173
Total
$442.50
Invoice Heat / Air Rotation
Emergency call: air rotation unit not operating; found thermostat set to 55°F; adjusted above 55°F and unit ran. Inspected belts/motors OK; outside-air dampers previously unhooked; monitored ~1 hour, no high-limit trip. Communicated findings via text.